Strain Gauge Measurement

Safety: Your demonstrator acts as your safety warden. Follow all instructions given by your demonstrator. If the evacuation siren sounds leave your bags and follow the instructions of your demonstrator and proceed to the evacuation area. Place all weights on holder when not in use. Electrical: Ensure that all electrical apparatus has no signs of obvious damage. Report any damaged apparatus to your demonstrator.Do not attempt to fix any broken apparatus. Report any damage to your demonstrator. General: No food or drink is allowed in the laboratory.    Introduction: Strain Gauges are used in many systems to measure the deformation of structures and materials, from this forces, moments and stress can be calculated. In this experiment we will be looking at a system of seven strain gauges spread over the length of a steel cantilever beam and will be comparing the measured strain and stress with thetheoretical strain and stress. Theoretical Strain: e =Mc/IE      Where:e   is strainM is the momentc is the distance from centre of beam to point where strain is bean calculatedE is the youngs modulusI is the second moment of inertia  Theoretical Stress:  O=M/S  Where: S is the section modulus  Measured Stress: O=Ee   Where:  is the measured strain Apparatus:        Slotted masses Strain Gauge Gauge Reader Steel Beam ClampConnecting Wires Rule Digital Callipers Side Cutters    Procedure: 1.   Measure all required beam dimension using digital callipers and tape measure.2.   Connect all strain gauge wires to the gauge reader (information below). Check that all gauges are working by weighting the beam and checking for a change in strain.3.   Document initial readings for all strain gauges.4.   Apply 1kg of mass to the beam and document the new strain readings. Repeat for 2 and 3kgs.5.   Remove 1kg of mass and document the new readings. Repeat until all masses are removed. Gauge Reader As seen in Figure 1 the gauge reader consists of two banks and twelve position allowing up to 24 strain gauges to be positioned simultaneously. The reader has already been calibrated for 120ohm strain gauges with a gauge factor (k) of 2.09. Connecting a strain gauge 1.   Disconnect the power2.   Choose a free position in a bank and connect the white and black wires to the black pin and red wire to the red pin.  3.   Connect Power.4.   Move position and bank dials to the strain gauge position5.   Deform the material to ensure the strain gauge is working   Figure 1 Gauge Reader    Report: Provide an individual report. Although no minimum word count provided, I expect a high quality 3rd year engineers report. It must include (but not limited to). Summary: Contents: Introduction: Procedure:*Results: *Conclusion/Discussion: Appendices:   *emphasis should be put on these areas.

Are you looking for a similar paper or any other quality academic essay? Then look no further. Our research paper writing service is what you require. Our team of experienced writers is on standby to deliver to you an original paper as per your specified instructions with zero plagiarism guaranteed. This is the perfect way you can prepare your own unique academic paper and score the grades you deserve.

Use the order calculator below and get started! Contact our live support team for any assistance or inquiry.

[order_calculator]